Transformers from 100kVA to 50MVA, medium voltage switchgear up to 40.5kV. IEC and UL certified with Type 2B arc-resistant enclosures for mission-critical power distribution.
UL 1558 / 891
IEC 62271
ISO 9001
IEEE 1547
EU Compliant
NFPA 70E
Oil-immersed and dry-type transformers
Transformers are the critical link between power generation and distribution. Our transformer lineup covers the full spectrum from 100kVA distribution units to 50MVA power transformers, each designed for specific application requirements.
Oil-immersed transformers offer superior cooling efficiency and are ideal for outdoor installations. Our OFW series achieves ONAN/ONAF cooling configurations with temperature rise ≤55K, ensuring reliable operation in ambient temperatures up to 45°C.
For indoor applications where fire safety is paramount, our cast-resin dry-type transformers offer Class F/H insulation with zero fire risk. Ideal for hospitals, high-rise buildings, and underground installations.
| Model | Capacity | Primary | Type |
|---|---|---|---|
| OFW-500 | 500kVA | 10kV | Oil |
| OFW-2000 | 2000kVA | 10kV/35kV | Oil |
| OFW-10000 | 10MVA | 35kV | Oil |
| DRY-500 | 500kVA | 10kV | Dry-type |
| DRY-2000 | 2000kVA | 10kV | Dry-type |
| DRY-5000 | 5MVA | 35kV | Dry-type |
Related Technical Articles:
Get detailed technical specifications, pricing, and project consultation.
Download Now →Arc-resistant, IEC compliant distribution
Switchgear is the control center of any power distribution system. Our medium voltage switchgear is engineered for arc flash protection, operator safety, and reliable operation under fault conditions.
Our switchgear meets IEC 62271-200 Type 2B arc-resistance classification, meaning arc gases are safely vented away from personnel through dedicated ducts. This is critical for facilities where operators work near energized equipment.
Our switchgear uses vacuum interrupter technology (VCB) instead of SF6 gas. VCBs are maintenance-free, environmentally inert, and face no regulatory restrictions. SF6 has a global warming potential 23,500x that of CO2.
| Model | Voltage | Interrupting | Arc Class |
|---|---|---|---|
| KYN28-12 | 12kV | 31.5kA | Type 2B |
| KYN61-40.5 | 40.5kV | 31.5kA | Type 2B |
| KYN28A-12 | 12kV | 40kA | Type 2B |
| VCB-Pro | 12-40.5kV | 25-40kA | VCB |
Modern 10kmv+ microgrids combine multiple power sources—utility, generators, and battery storage. Each source contributes different fault current levels.
Switchgear must be rated for the maximum combined fault current from all parallel sources.
Related Technical Articles:
GLOBAL DELIVERY IN JUST 30 DAYS
Custom transformer and switchgear solutions engineered for your specific application requirements.